Herunterladen Inhalt Inhalt Diese Seite drucken

Fitting The Inlet And Outlet - Kessel Aqualift F Basic Anleitung Für Einbau, Betrieb Und Wartung

Vorschau ausblenden Andere Handbücher für Aqualift F Basic:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
3.3

Fitting the inlet and outlet

Preparation
Risk of functional problems due to suspended matter and solids
deposited on the level sensor.
If the inlet is to be at the muffs <26B > or <26C>, the respective
muff must be sawn off at the given cutting edge.
If the inlet to the system tank is to be via position <26C>, the level
sensor <27> has to be exchanged with the cover of the service
opening <30> . To do so, proceed as described below
Unscrew each of the 4 fastening screws <1> and dismantle the
two assemblies accordingly. Position the anti-twist protection
device <2> correctly
The inlet can be mounted at various positions on the system tank:
24
DN 80
26A
DN 50 or DN 100
26B
DN 100
26C DN 100
26D Scoring surface, maximal DN 100. Make sure that no
backwater enters the inlet pipe
Installing the inlet
Dismantle the level sensor if necessary
Mount the inlet on the system tank
Installing the outlet
Connect the pressure pipe to the connection <24>.
Installation
42 / 180
2
Ill. [7]
24
26A
30
26C
26D
Ill. [8]
27
1
30
26C
27
26B
2017/11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis