Herunterladen Diese Seite drucken

Wisniowski INTRO 600 Technische Dokumentation Und Beschreibung/Montage Und Bedienungsanleitung Seite 13

Intro-serie

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
[D000665]
Rs
- Door unlock in sectional doors
Rs
- Door unlock in up & over doors
PB-GND
- START in, NO contact
PE-GND
- photocell in, NC contact (must be activated)
DOOR-GND - STOP in, NC contact
+12V-GND - out (accessories power supply)
+24V-GND - out (warning lamp power supply)
So
- Opening width
Ho
- Opening height
[C000383] Do not stay, pass, run or drive un-
der the door when it is in motion. Before ope-
ning or closing, ensure that no persons, and
especially children or any objects, are in the
path of the moving garage door. No persons,
objects or vehicles are allowed to stay within the
clearance of the open door.
[C000384] Do not use the garage door to lift
any objects or people.
[C000385] Do not use the door when
inoperable.
[D000138] 4. BUILD DESCRIPTION AND TECHNICAL SPECIFICATION
The drive makes a set with a slide rail of a relevant length which is necessary
for its correct operation. It is mounted on the end of a steel slide rail. The rail is
equipped with a driving chain which drives a catch. The catch is integrated with
a door. The operator drives the door via an arm fastened to the chain holder
from one side, and to the door leaf top part on the other side. The drive is pro-
tected with overload switches; when the door leaf meets resistance on the way,
the drive will stop and reverse.
[D000653] 4.1. TECHNICAL SPECIFICATIONS
Opening and closing force
Motor
Power supply
Rated power
Operating temperature
Duty (maximum switching count per
hour) 30
[A000102] 5. APPLICATIONS AND INTENDED USE
All products shall be used and operated as intended. Their selection and use
in building engineering shall follow the specific technical documentation of the
installation site prepared according to current laws and standards.
[D000688] The drive unit is intended for operating sectional and up-and-over
garage doors within the dimensional limits specified in the respective commer-
cial offer and the operating time limits specified in this Manual, and in compli-
ance with the technical data specified in this Manual.
The drive unit is intended for dry indoor rooms only. Do not use the drive unit
outdoors.
[C000446] The drive unit is intended for operating doors installed in single-fam-
ily houses.
The drive unit is not intended for collective garage rooms (with more than 2
parking places).
Technical Description
IIiO/INTRO/01/2017/ID-95874
Assembly and Operating Instructions – Drive unit for garage doors INTRO
INTRO 600
INTRO 1000
600 N
1000 N
18V DC 4Nm
18V DC 10Nm
230V AC 50Hz
230V AC 50Hz
165W
240W
-20 / +40 °C
-20 / +40 °C
30
30
[B000190] 6. SAFETY GUIDELINES
Minimum safety levels provided in the door closing edge as required by PN-EN
13241-1.
Door activation
method
Trained door
operators (private
premises)
Push-button control
Deadman control with
without electrical
the view of the door
latching
Pulse control with the
view of the door
Pulse control without the
view of the door
Automatic control
(automatic closing)
– main closing edge protection -
required
– photocells barrier - obligatory
[C000447] Photocells must be used whenever:
• the automatic door closing function is enabled;
• the remote control functionality is used;
• the controller is outside of the line of sight of the door;
• the door is not in the direct line of sight of the user;
• the door is intended to be operated automatically.
[C000448] If the door drive unit is operated with the automatic closing enabled
or the door opens directly to a public road or a public pedestrian pavement,
install a warning lamp as regulated by the laws of the country where the drive
unit will be operated.
[B000152] 7. REQUIRED INSTALLATION CONDITIONS
[B000206] The Manufacturer shall not be liable for any damage or operating
errors caused by incorrect installation or operation of this product.
Do not install the door in a room where finishing
works (i.e. plastering, grinding, etc.) are still to be
performed.
The flooring at the bottom gasket shall be level and built to ensure free outflow of
water. Ensure proper ventilation in the room (for drying of materials).
• [B000214] According to the current European regulations, a pow-
er-operated gate must be manufactured along with Directive
2006/42/EC. It must follow the following standards, as well: EN
13241-1, EN 12445, EN 12453, and EN 12635.
• [A000136] Before proceeding with the installation, a risk analysis
must be performed, including all safety conditions, as provided by
Appendix 1 Machine Directive, to indicate solutions to be used
with the installation (planning permission).
• [C000081] The drive must not be installed in an explo-
sion risk environment. Presence of flammable gases and va-
pours is a major risk factor.
• [C000449] Protect the drive unit against water.
• [D000142] Before any maintenance or inspection of
a garage door, disconnect the drive from power
source. Also a battery power supply should be disconnected if
it has been delivered.
• [B000007] It is prohibited to keep using the door, if any
faults in its operation, or damage of its components
are found.
In this case, immediately put the door out of operation, and con-
tact the authorized service centre.
• [D000140] The required header capacity is >500N.
EN
Usage
Not trained
Trained door
door operators
operators (public
(public pre-
premises)
mises)
Key-switch control
without electrical
Unacceptable
latching
– photocells barrier - optional
13

Werbung

loading

Diese Anleitung auch für:

Intro 1000