10.1.4 DDLM_Set_Prm Operating Parameters

Octet
Bit
Type
9
0
bool
1
bool
2
bool
3
bool
4
bool
5
bool
6
bool
7
bool
Because the DME 3000 is a linear encoder, which measures the absolute distance between the
material scanned and the sensor, the "Code Sequence" and "Scaling function control" parameters are
ignored.
The "Class 2 Functionality" must be set to '0' if the diagnosis data described below should be
compatible with Class 1.
Class 2
Commissioning
Functionality
Diagnostic
x
0
1

10.1.5 Diagnostic Information

7
Octed string
8
unsigned 8
9
0
bool
1
bool
2
bool
3
bool
4...7
bool
10
unsigned 8
11...14
unsigned 32
15...16
unsigned 16
The bits 0...7 from Octed 8 are set fixed to "0". Octed 9 of the diagnosis data reflects Octed 9 of the
transmitted parameter data.
The values for the encoder type "Measuring Step in nm" and "Distinguishable revolutions" are fixed.
The diagnosis data are only transmitted if a fatal error occurs in the DME.
Output
Code Sequenz (CW/XCW)
Class 2 Functionality (on/off)
Comissioning diag. (on/off), optional
Scaling function control
Reserved for future use
Reserved for future use
Reserved for manufacturer
Reserved for manufacturer
Length of the "Diagnostic Information"
0
6 Byte standard diagnosis
1
16 Byte Class 1 diagnosis data
1
61 Byte Class 2 diagnosis data
Extended diagnostic header
Alarms (not used)
Operation status
Code sequence status
Class 2 functionality supported
Commissioning diagnostics supported
Scaling function status
not assigned
Encoder type 00 ... FF
Singleturn resolution (rotary)
or Measuring Step in nm (linear)
Distinguishable revolutions
DME 3000-2 _ _P
Software 1.1
Default
0
7
1.000.000 nm
0