Distribution of the output data:
BIT0-23:
BIT24-28:
BIT29:
BIT30:
BIT31:
Offset value:
The offset value is added to the DME measurement value, and the total is output as a new value. The
offset value is normally used to correct a known distance offset.
Reference value:
The DME measurement value is replaced by the reference value in the reference value transmission.
All other measurements of the DME refer to the reference value from this point in time.
CAUTION:
Reference value and offset value are NOT stored permanently in the DME, i.e., the values must be
retransmitted after a power outage.

4.2.10 Standards

DIN 19245 Profibus FMS (Field Bus Message Specification)
DIN 19245-2 Profibus DP (decentralized periphery)
IEC 1158-2 Profibus PA (process automation)
EN 50170 Volume 2 European Field Bus Standard

4.2.10.1 Commissioning aids and error displays (SERVICE)

This menu is provided for selecting the following service parameters:

ALIGN

Reception level display

TIME

Operating hours display
INT. STATUS Interface status: Status display of the interface line
ERR. STATUS Error Status: Device error status display
SER-NR.
Serial number of the device
RESET
Reset of all parameters to status as delivered
4.2.10.2 ALIGN
This function is an aid for determining the achievable accuracy with respect to a specific object. The
magnitude of the reflected transmitted power is displayed in dB.
The following association holds approximately:
Object
Remission
black
6%
gray
18%
white
90%
glossy
max. 300%
4.2.10.3 TIME
Displays the total accumulated operating hours.

4.2.10.4 INTERFACE STATUS

The interface status of all interface lines is displayed here to facilitate trouble shooting. The logic
levels of the interface lines are symbolized:
LOW = 0, HIGH = 1.
The interface lines are designated as follows:
Q1
Q2

4.2.10.5 ERROR STATUS

The chief impending failure and warning messages are displayed here.
Offset or reference value, which should be transmitted to DME
Not assigned
Laser on/off
Transmit offset value
Transmit reference value
Measuring
Measuring
distance 1 m
distance 2 m
-94 dB
-102 dB
-88 dB
-75 dB
-70 dB
Measuring
distance 4 m
-
-98 dB
-105 dB
-90 dB
- 96 dB
-85 dB
- 90 dB
DME 3000-2 _ _P
Software 1.1
Measuring
distance 8 m
-
-
- 106 dB