Page 38

6 Technical Data

Type
Order number
Power supply voltage
Residual ripple
Power consumption
Optical transmitter
Laser protection class
Service life
(at 25 °C)
Light spot (
Measuring distance 8 m)
Filter
Switching outputs
Q1, Q2
Output current
Capacitive load
Switching outputs Q1, Q2
Switching limit
Switching hysteresis
Interfaces
Baud rate
Type of protection
Electric protection class
EMP compatibility
Shock stress
Ambient temperature
Storage temperature
Weight
Measuring range
Resolution
Accuracy (for measuring distance)
white
90%
gray
18%
black
6%
Environmental conditions constant
minimum switch-on time 30 min.
23 °C air temperature / 977 hPa barometric
pressure
Reproducibility
white
90%
gray
18%
black
6%
Environmental conditions constant
minimum switch-on time 30 min
Temperature drift
Measurement reading output
Initialization time
DME 3000- 211P
1 018 064
DC 18 ... 30 V
5 Vpp
< 6 W
Laser diode (red light)
2 (IEC 825-1 / EN 60825-1)
MTTF 50000 h
d ∼ 5 mm
B
HIGH: Uv - ≤ 2 V LOW: < 2 V
100 mA
100 nF
invertable: Q / Q
adjustable in mm steps
adjustable in 2 mm steps 0 ... 254 mm
Profibus DP with RS 485
4,8 / 9,6 / 19,2 /38,4 / 93,75 / 187,5 / 500 / 1500 / 12000 kBaud
IP 65
VDE Class 2
CE
IEC 68
-10 ... 45 °C
-25 ... 75 °C
approx. 980 g
100 mm ... 8000 mm
0.125 mm
1 m
± 5 mm
± 5 mm
± 10 mm
1 m
1 mm
2 mm
5 mm
typ. 0.4 mm/K
Profibus
21 ms
5 s
411P
1 019 149
limit values, wrong polarity protected
2 m
4 m
± 5 mm
± 10 mm
± 10 mm
± 30 mm
± 20 mm
--
2 m
4 m
2 mm
5 mm
5 mm
25 mm
25 mm
--
typ. 0.2 mm/K
DME 3000-2 _ _P
Software 1.1
212P04
1 019 697
without load
Filter
short circuit proof
(Design voltage 50 V)
6 m
8 m
± 20 mm
± 30 mm
--
--
--
--
6 m
8 m
10 mm
25 mm
--
--
--
--
typ. 0.4 mm/K

Werbung

Kapitel

Inhaltsverzeichnis
loading