f) Setting Signal Interval
The signal interval can be programmed for each of the two channels. The term "Signal Interval"
means that switching commands will be sent at a defined switching interval in the case of a
continued exceeding of the threshold temperature. The temperature measurement for the
respective channel is carried out at the same time interval.
The time periods 48, 72, 96 and 120 seconds are available to adjust the signal interval.
2
1
or
2
1
2
1
Please note:
• The lower the signal interval is set, the shorter the battery life will be.
• The signal interval should always be shorter than the activation period (see next section,
Chapter 11. g), so that the device also remains on continuously when the threshold
temperature is exceeded.
52
4
Channel 1
3
Channel 2
4
3
Press for 5 seconds
LED "D1" is lit
LED "D2" flashes
4
3
Enter signal interval
LEDs "D1" and "D2"
go out
• For channel 1 press the "1" and "4" buttons
together for at least 5 seconds until the LED
"D2" flashes.
For channel 2, press the "2" and "3" buttons.
• Then enter the signal interval in accordance
with the following table:
Button pressed
1
2
3
4
• Enter the desired time by pressing one of the
four buttons.
• Once the time is entered the LEDs go out.
Signal interval
48 seconds
72 seconds
96 seconds
120 seconds