3-2-4 Avoiding Breaks in
Operation Due to Dead Batteries
If you use both an internal battery pack and an external
battery connected to the DC IN connector at the same
time, you can avoid breaks in operation due to the dead
batteries.
When the external battery begins to fail and
an internal battery pack is also used
Remove the DC cable of the external battery from the
DC IN connector. The power source will switch to the
internal battery pack.
When the external battery begins to fail and
an internal battery pack is not used
First load the DNV-5 with a fully charged internal
battery pack, then remove the DC cable of the external
battery from the DC IN connector. The power source
will switch to the internal battery pack. To use an
external battery again, connect a fully charged external
battery to the DC IN connector before unloading the
internal battery pack. The power source will switch to
the external battery.
Continuous operation when operating with
only an internal battery pack
First, connect a fully charged external battery to the
DC IN connector, then change the internal battery.
Notes
• Whenever an internal battery pack is loaded and an
external battery is connected to the DC IN connector,
the external battery is always used as the power
source.
• There may be some noise on the video signal at the
instant the power sources are switched.

3-2-5 Using an AC Adaptor

Using an AC-550/550CE Adaptor
Connect the DNV-5 through an AC-550/550CE AC
Adaptor as illustrated, then turn on the AC adaptor
power switch.
AC-550/550CE
AC Adaptor
LO C K
DC OUT
DC cable
DC IN
(supplied with the
AC-550/550CE)
Using an AC-550/550CE AC Adaptor

Using an AC-DN1 AC Adaptor

Attach an AC-DN1 AC Adaptor to the DNV-5 in the
same way as with a battery pack, and connect the
system to an AC power supply.
3-2-6 Using the Anton Bauer
Ultralight System
By fitting the DNV-5 with the Anton Bauer Ultralight
System, and setting the LIGHT switch to the AUTO
position, you can switch the light on and off
automatically as you start and stop VTR operation.
(This system operates with lights powered by 12 V,
with a maximum power consumption of 30 W.)
Chapter 3 Setting Up the Camcorder
Power switch on
To wall
outlet
AC-DN1 AC Adaptor
To wall outlet
3-5(E)