Herunterladen Inhalt Inhalt Diese Seite drucken

Control Unit - Kessel Aqualift F Anleitung Für Einbau, Bedienung Und Wartung

Kessel-pumpstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Control unit

• The control unit can be operated without needing to open
the control unit cover. However, the cover can be opened
for service work.
• Opening the cover of the control unit reduces the IP 54 ra-
ting of the control unit. It should be checked if the risk is pre-
sent that moisture or spraying water can access the open
control unit. If this is the case power should be disconnec-
ted from the control unit before opening the cover. In case
of any questions contact a licensed electrician.
9.1 Control unit connection plan for single pump Aqualift F
9.2 Control unit connection plan for twin double) pump Aqualift F
9. Control unit
• The setting on the motor protection switch must match the
power of the pumps in the Aqualift F unit.
The motor protection switch setting should not be changed
by the operator.
• After settings have been successfully completed, make
sure to close the control unit's cover and secure properly
which will assure the proper IP protection class that the con-
trol unit offers.
73

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis