3.1 Explosion proof pumps according to ATEX
Rated input P1
Type
Rated output P2
Operating voltage
Frequency
Current
Cables
Fuses
Protection
Wastewater temp.
Max running time at 40 deg C
Pump weight
• Operating modes:
Classifications:
• Pumps with the TPF . . . ex identification according to Unit Group II, Unit Category 2G (Explosion endangered areas
Zone 1 and 2) are designed for installation in atmospheres containing dangerous gases which require the Explosi-
on Group IIB and the Temperature Class T4. Pumps constructed according to this designation comply with the igni-
tion protection type „pressure protection encapsuled`.
Performance Curve
35
30
25
20
15
10
5
0
0
0
3. Technical Data
10 m Length 7 x 1,5 mm
II 2G Ex d IIB T4 Gb LCIE 06 ATEX 6043X
0081
Pump submerged – Continuous operation S1
Q
according to DIN 1986 (v
min
for DN 50
TPF 1,3 kW
5
1
2
47
1.75 kW
TPF 1.3
1.3 kW
400 V DS
50 Hz
3.56 Amps
2
3 x 16 Amps
IP 68
40 º C
640 minutes (see settings in chapter 5.7)
39 kg
= 0,7m/s)
min
for DN 80
TPF 1,9 kW
10
15
3
4
2.6 kW
TPF 1.9
1.9 kW
400 V DS
50 Hz
4.5 Amps
10 m Length 7 x 1,5 mm
3 x 16 Amps
IP 68
40 º C
39 kg
Flow Q
20
(cubic meters / hour)
5
(liters / second)
2
EX