5.11
Control unit (Tronic)
5.11.1

Installing the control unit

Select installation position taking the following into
account:
There is a safety socket in the direct vicinity of the con-
trol unit.
The connecting cable from the wastewater pump and
float switch can be installed correctly and routed to the
control unit.
The control unit can be fastened safely and suffi-
ciently.
Unscrew housing cover.
Fit all three fastening screws (drilling template included
in the scope of delivery). In doing so, ensure that the dis-
tance (A) between the screw heads and the fastening
surface is ca. 3 to 4 mm.
Hang the control unit on the three fastening screws and
press downwards gently. (1)
016-102_01
Pumping station / Installation and operating manual