Orbit Controls AG
Command
[SOURce]
:MODE?
:HVResistance
[:LEVel] <DNPD>
:VOLTatge?
:CURRent?
[:LEVel]?
:TIMer
[:LEVel]?
:VOLTatge?
:SHORt
:CURRent?
: HVCapacitance
[:LEVel] <CPD>
:VOLTatge?
[:LEVel]?
: PSPolarization
:TOTaltime?
:VOLTatge?
:RESistance0 <DNPD>
:RESistance0?
:RESistance1<DNPD>
:RESistance1?
:RESistance2<DNPD>
:RESistance2?
:RESistance3<DNPD>
:RESistance3?
:TTIMe1 <DNPD>
:TTIMe1?
:TTIMe2 <DNPD>
:TTIMe2?
:TTIMe3 <DNPD>
:TTIMe3 ?
: DPParameters
:RESistance0<DNPD>
:RESistance0?
:CDARatio <DNPD>
:CDARatio?
:CPIndex <DNPD>
:CPIndex?
:CPRatio <DNPD>
:CPRatio?
:ROUTput?
:RCOunt?
:VOLTatge?
:TOTaltime?
Tab XI. SCPI Source commands
Betriebsanleitung
SOURce Command Summary
Path to SOURCE subsystem.
Returns mode the Calibrator is set to.
Sets Calibrator to HVR mode.
Sets the resistance value for HVR mode
Returns the measured voltage on the open output
terminals.
Returns the current flowing through the selected resistor.
Returns the set value for the HVR mode.
Sets Calibrator to TIM mode.
Returns the set value for the Timer mode.
Returns the measured voltage on the open output
terminals.
Sets Calibrator to SHORT mode.
Returns the current.
Sets Calibrator to HVC mode.
Sets the capacitance value for HVC mode
Returns the measured voltage on the open output terminals.
Returns the set value for the HVC mode.
Sets Calibrator to Programable simulator of polarization mode.
Returns the measured total time.
Returns the measured voltage on the open output terminals.
Sets the resistance value R0 for PSP mode.
Returns the resistance value R0 for the PSP mode.
Sets the resistance value R1 for PSP mode.
Returns the resistance value R1 for the PSP mode.
Sets the resistance value R2 for PSP mode.
Returns the resistance value R2 for the PSP mode.
Sets the resistance value R3 for PSP mode.
Returns the resistance value R3 for the PSP mode.
Sets the time value T1 for PSP mode.
Returns the time value T1 for the PSP mode.
Sets the time value T2 for PSP mode.
Returns the time value T2 for the PSP mode.
Sets the time value T3 for PSP mode.
Returns the time value T3 for the PSP mode.
Sets Calibrator to Dielectric and polarization parameters mode.
Sets the resistance value R0 for DAR mode.
Returns the resistance value R0 for the DPP mode.
Sets the DAR coefficient for DPP mode.
Returns the coefficient of DAR value for the DPP mode.
Sets the PI coefficient for DPP mode.
Returns the coefficient of PI value for the DPP mode.
Sets the PR coefficient for DPP mode.
Returns the coefficient of PR value for the DPP mode.
Returns the actual output resistance for the DPP mode.
Returns the counted resistance value R0*coefficient for the
DPP mode.
Returns the measured voltage on the open output terminals.
Returns the measured total time.