Chapter 5. Machine adjustment and setting up
5.2.4. Parameter settings for the AUTOMATIC PROGRAM (from the ''Data'' key)
At this point the programmable parameters display page appears; press the  button to scroll through the various
pages:
To modify the set values (e.g. FRONT FILM from 20mm to 30mm) follow the procedure below.
Press the numerical value (e.g. 20).
Press the "Data" button.
PACKET HEIGHT [mm]
Adjusts triangle aperture. Values: 35 ÷ 240.
PACKET LENGTH [mm]
If it is set on AUTO the film will be sealed when the photocell reads the end of the
product. This is recommended for products with a regular shape. If it is set on MAN
the function deactivates the photocell reading of the end of the product. In this case
the film is sealed by setting the "PACKET LENGTH" variable. Values: 1 ÷ 600.
FRONT FILM [mm]
Adjusts the quantity of film to leave in front of the pack. Values: 0 ÷ 300.
REAR FILM [mm]
Adjusts the quantity of film to leave behind the pack. Values: 0 ÷ 900.
Indicates the minimum variable setting.
Enter the new value and press
"Enter".
FRONT TEMPERATURE [C]
Adjusts the front bar (short) sealing temperature. Values: 0 ÷ 240.
SIDE TEMPERATURE [C]
Adjusts the side bar (long) sealing temperature.
Values: 0 ÷ 240 (Pratika 56, 56CS, 56MPE); 0 ÷ 365 (Pratika 56MPS).
SEALING TIME [s]
Adjusts the bar sealing time. Values: 0 ÷ 3.
SEALING HEIGHT [mm]
Adjusts the sealing position with respect to the belt. Values: AUTO / MAN.
If set at AUTO sealing is performed at half the height of the product. Ideal for standard
products.
If set at MAN sealing is performed at the set measurement (measured starting from
outfeed belt surface). Values: 0 ÷ 120.
SEALING PRESSURE
Regulates the pressure of the film sealing bar to optimise the cut.
Values: MIN / MED / MAX
Indicates the maximum variable setting.