Chapter 5. Machine adjustment and setting up

5.1.2. Luminous column

The machine is equipped with a luminous column with multicolour LED lights (green, yellow, red) which, based on the
combination of colours and buzzer, signals the machine status at all times.
Machine status
Start in Manual
Start in Automatic
Warm-up
Maintenance
Automatic stop
Manual stop
Homing
No power
Safety excluded during Start
Safety excluded during Stop
Roll end in Automatic Start

5.2. Start-up

Turn the main switch (Q1) into pos. 1 and press the "RESET" (S2) button.
The display switches on and the screen with the "minipack-torre" logo appears. Press the logo.
The main screen is displayed:
When the machine is switched on, the numbers that indicate the temperature of the
front and side sealing bars start flashing. Once the bars have reached the
programmed temperature, they stop flashing. Until the bars reach this temperature,
the cycle may only be started in MANUAL mode (not AUTOMATIC mode).
During the heating phase the "Alarm" button is red since the "A024: MACHINE
HEATING" alarm is active. Once the set temperature has been reached, the alarm
resets itself and the button becomes green..
37
Luminous column
Green
Green
Green
Yellow
Yellow
Yellow
Red
Red
Red
Red
Green
Green
Red
Yellow
Yellow
Red
Green
Green
EN
Buzzer
No
No
Yes
Yes
Yes
Yes