10.1 Cancelling a device from a
radio group
You must cancel a device from a radio group in
the following cases:
Removing device from an
existing radio group and
connecting it to another group
Removing the defective device
from the radio group
In the radio group from which the device
was removed, you must set all the devices
to factory settings and re-connect them:
f Observe chapter 6.1 "Setting up the
radio group" on page 61.
f Observe chapter 7 "Expanding a
radio group and learning mode" on
page 63.
f Observe chapter 6.2 "Completing a
radio group" on page 62.
66
Operating Manual: PX-1C - Smoke Alarm Device with Radio Link
11 Alarm forwarding
and alarm stop
Alarm forwarding takes place in two direc-
tions with the following forwarding times:
Alarm forwarding within a
radio group or a shared radio
group = approx. 20 seconds.
Alarm forwarding from
the radio group to the shared
radio group = approx. 60 seconds.
There is no alarm forwarding from the
shared radio group to the individual ra-
dio groups.
Repeater function
Through the repeater function, radio sig-
nals are forwarded from one signalling
device through available devices to un-
reachable devices.
If you need specific and/or
c o m p l e x c o n n e c t i o n f u n c -
tions for the alarm forwarding,
please contact the manufacturer
(see chapter 15 "Accessories, spare
par ts and product suppor t" on
page 75).