Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Test - pyrexx PX-1C Betriebsanleitung

Vorschau ausblenden Andere Handbücher für PX-1C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

(5) Finalise the shared radio group on a
device of the shared radio group.
f Observe chapter 6.2 "Completing a
radio group" on page 62.
5 The shared radio group is in oper-
ation.
f To test, perform a connection test (see
chapter 9.2 "Connection test to the
shared radio group" on page 65).
64
Operating Manual: PX-1C - Smoke Alarm Device with Radio Link

9 Connection test

9.1 Radio group connection test
You can test that the group is connected
correctly (radio group or shared radio
group) as follows:
(1) Press and hold the testing/stop
button of any device in the group for
approx. 12 seconds.
After approx. 1 second, the
test tone will sound.
(2) After the second test tone, release
the testing/stop button.
All other devices in the radio
group emit a short test tone.
5 Successful connection test of the
radio group.
All devices connected within the radio
group send a short sound signal. If devic-
es are defective, they remain silent and
can thereby be identified (see chapter 17
"Alarm and alert tones" on page 78).