8 Alert tones and alarm signals
To reset the PX-AR to the default status,
press and hold the configuration button
The PX-AR alarm relay signals different
events using different alert tones and
alarm signals:
Alert tones
1. "Caution: Low battery charge"
90 Seconds
If the battery charge has reached a critical
point, the PX-AR signals this with a short
beep at regular intervals.
10 Seconds
2. "Group participant lost"
If you have initiated a connection test us-
ing a PX-1C and a participant in the radio
group has been lost, the PX-AR, as well
as all other connected PX-1Cs, produces
34
a triple-beep at regular intervals.
You can therefore check which group par-
ticipant is not producing a signal tone and
is therefore not connected.
Alarm signals
1. Smoke alarm:
If a PX-1C in the radio group triggers a
smoke alarm, then the PX-AR and the
radio alarms produce 2 beeps at short
intervals.
2. Temperature alarm:
If a PX-1C in the radio group triggers a
temperature alarm, then the PX-AR and
the radio alarms produce a single beep at
short intervals.
Operating Manual: PX - AR Alarm Relay
0.5 Seconds
1 Second
EN