Problem description
The heating is perma-
nently active
The heating is perma-
nently off
The heating heats up
very slowly
Even though the heat-
ing is active, it is per-
manently too cold
Despite the heating
breaks of the radia-
tors, it is permanently
too warm
36
Possible causes / solutions
„Rapid heating process" function activated at the re
mote control? – if so, deactivate it
Outdoor temperature sensor is defective or not accu
rately positioned? (s. 7.3 „sensor faults")
Temperature value for summer operation is set too
high?
„Heating curcuit off" function activated at the remote
control?
Pump setting of the SKSCEM1 is set to „0" (off)?
Flow temperature sensor defective? (s. 7.3 „sensor
faults")
Temperature value for summer operation is set too
low?
Adjusted mixer runtime value is too low?
Adjusted heating curve is too low?
- Maximum flow temperature is too low?
Position selection of the remote control is too low?
Adjusted time is accurate?
Time frame of the night correction is accurate? (pre
vention of undesired temperature decrease)
Adjusted heating curve is too high?
- Maximum flow temperature is too high?
Position selection of the remote control is too high?
Day correction is too high?
GB