In both cases, release the start button.
If different numbers appear on the display, contact tech-
nical service.
3 INSTALLATION
Make sure that the supply voltage matches the voltage indi-
cated on the specifications plate of the welding machine.
When mounting a plug, make sure it has an adequate capa-
city, and that the yellow/green conductor of the power sup-
ply cable is connected to the earth pin.
The capacity of the overload cutout switch or fuses installed
F
G
B
C
D
H
A
I
E
O
AB
N
M
L
Y
J
in series with the power supply must be equivalent to the
absorbed current I1 of the machine.
Any extension cords must be sized appropriately for the
absorbed current I1.
3.1 START-UP
Only skilled personnel should install the machine. All con-
nections must be carried out according to current regula-
tions, and in full observance of safety laws (regulation CEI
26-10 - CENELEC HD 427).
3.2 DESCRIPTION OF THE EQUIPMENT
Z
T
V
AA
W
X
U
S
R
Q
P
AE
AC
AD
9