'L1 - L7' LEDs (3)
LED
L1
L2
L3
L5
L6
L7
LED L1 on:
The error description and the corresponding display on the power source are described
in the 'Robot interface' leaflet (42,0410,0616):
chapter entitled 'Output signals to robot', section 'Error number UBST'
L1 LED flashing - error is indicated using the flash code:
Flash code
Error
code
1
62
Indicator
Meaning
On / fla-
Error occured in module
shing
On
Communication on the Fronius
LocalNet active
Flashing
Ethernet stack sendind data
Flashing
UBST OS running
On
Physical Ethernet connection
present
Flashing
Ethernet data transfer active
(1)
(2)
Error
Error description
argu-
ment
1
Max. Ethernet frame size exceeded
2
Incorrect mailbox type
4
UDP data underflow on port 15000
5
UDP data overflow
6
UDP data underflow on port 15001
7
Incorrect UDP port
8
Error during stack initialisation
9
Invalid function
(1)
Rapid flashing:
Start of the error code
(2)
First slow pulse:
Type of error
(3)
Second slow pulse:
Error location
(3)
Remedy
See error number
Table / After sales ser-
vice
Remedy
Switch interface