F THE EXTRACTOR FAN DOES NOT WORK PROPERLY AND
INCREASED OPERATING NOISE
 Incorrect dimension of the air duct.
 Obstruction in the air duct.
 The diameter of the air duct from the appliance to wall-box inclusive should be
120/150 mm; otherwise, the capacity of the motor may be decreased.
 If you have installed a fly screen on the wall-box, the air vent may be obstructed.
Check by removing the fly screen.
 If the cover panel of the wall box is equipped with firm and slanted slats, the air
vent may be obstructed. Check by removing the cover panel.
 Install a cover panel with moveable slats, which do not obstruct the air vent.
 Check condition and cleanliness of the filters.
 Check if the air which is extracted by the extractor fan is replaced to avoid
negative pressure.
 Check condition and cleanliness of the filters.
 Check if the air which is extracted by the extractor fan is replaced to avoid
negative pressure.
 When you run your appliance in recirculating mode, check if the carbon filter has
been replaced on time (min. every 3-4 months).

9.3 Error codes

Error codes are displayed on the timer indicator.
E
RROR
CODES
0 1
NTC short circuit on the
0 2
0 3
of the hob surface is too
I
N EXTRACTION MODE
I
N RECIRCULATION MODE
D
ESCRIPTION
Hob surface, open
circuit
hob surface
The NTC temperature
high
,
CHECK THE SCHEDULE BELOW
M
Disconnect the appliance from mains
and contact the aftersales service.
Disconnect the appliance from mains
and contact the aftersales service.
Wait until the appliance has cooled
down. If the problem cannot be
solved, disconnect the appliance from
the mains and contact the aftersales
service.
/