G
H
J
K
L
The additional accessory set required for extraction mode and / or
recirculation mode operation is available from specialised dealers
(accessory set: DA-KS1, article no. 50864).
2.4.3 Installation example: recirculation mode
S
AFETY INSTRUCTIONS REGARDING THE INSTALLATION
When installing the appliance, ensure optimal heat radiation to maintain the
operating safety.
The wall and the reach of the heat radiation above the worktop must be made of
heat-resistant materials.
To avoid any damage, the sandwich layer and adhesive must resist heat.
Provide an installation opening relevant to the dimensions on the drawings in
chapter 2.3 S
ELECTION OF THE INSTALLATION ENVIRONMENT
For installation and use, a minimum of 50 mm space shall be preserved around
the installation opening.
The thickness of the worktop must be at least 30 mm. Choose heat-resistant
materials for the work top only to avoid any deformation caused by the heat-
radiation of the appliance.
The safety distance between the induction hob and a wall cupboard above must
be at least 760 mm.
The height of the kitchen base must be at least 100 mm to ensure
sufficient space for the air ducts under the installation cabinet.
WARNING! All air ducts must run inevitably under the bottom of the
installation cabinet in the area of the kitchen base.
C
URVED CONNECTING PIECE
R
UBBER BAND
F
/
OAM STRIP
SELF
S
CREWS
M
OUNTING BRACKET
(90°)
-
ADHESIVE SEAL
M4*10
/ D
.
IMENSIONS
~
~
100