9.2 Trouble shooting: extractor fan
P
OSSIBLE CAUSE
1. The plug of the appliance is not
connected to the socket.
2. The plug has become loose.
3. The socket is not supplied with
energy.
4. The fuse is switched off.
5. The voltage is too low.
1. Ventilation damper blocked.
2. Motor mounting defective.
1. Motor defective.
1. One-way valve is leaky.
1. Motor not properly fixed.
2. Extractor fan not properly fixed.
1. Too much draught because of open
doors and / or windows.
If the appliance has a malfunction not noted on the schedule above or if you
have checked all items on the above schedule but the problem still exists, please
contact the aftersales service.
M
ALFUNCTION
(
)
S
T
HE APPLIANCE DOES NOT WORK AT ALL
L
IGHT IS ON BUT MOTOR DOES NOT WORK
A
BNORMAL MOTOR
S
MEAR OF OIL
A
PPLIANCE VIBRATES
I
NSUFFICIENT EXTRACTING CAPACITY
M
EASURE
1. Connect the appliance to the mains
properly.
2. Check the plug.
3. Check the corresponding socket by
connecting it with another appliance.
4. Check the fuse box.
5. Compare the data on the model plate
with the data of your energy supplier.
1. Remove blockage.
2. Replace motor.
-
:
SMELLS
1. Replace motor.
:
1. Seal the valve.
:
1. Fix motor properly.
2. Fix extractor fan properly.
2. Close the doors / windows.
(
)
S
:
:
:
~