To route the cable through the weight tower:
1. Locate the pulley positioned over the opening where the cable will thread
up through the weight tower. Using a ³ ₄-inch socket wrench and a ³ ₄-inch
open-end wrench, remove the bolt, and then remove the pulley and cable
retainer.
Figure 18: Removal of pulley and cable retainer
Seated Dip Assembly Guide: Routing the Cable Assembly
2. Thread the cable up through the weight tower frame. Replace the pulley
and cable retainer making sure that the cable is positioned in the pulley
trough and under the cable retaining bracket. Tighten the bolt to 500 in-lb
(56 N-m) of torque.
Note: When properly installed, the cable retainer keeps the cable securely
seated in the pulley. However, the retainer must not contact the cable
while the cable is under load (for example, during a workout).
Figure 19: Proper position of cable under cable retainer