ENGLISH
6. Installation of the drain hose
1. Connect the drain pipe with the pipe already prepared and coming out of the indoor unit.
2. Secure the joint with electrical tape.
Outdoor pipe
Tape
15. Press " Confirm " after entering the password.
16. Select and connect to the "Smart Life-xxx" network. Once connected, return to the App. If the
Note:
device has been added successfully will be a message on the Home page, after that you can click on
Wrap the tube with insulating material to prevent condensation from forming outside the tube
the air conditioner for operations.
7. Electrical connection of the indoor unit
1. Open the frontal panel of unit , to access the electric box.
Then remove the fixing screw on the wiring compartment cover .
Front panel
2. Pass the power and communication cable through the back of the indoor unit and then pull it out
from the front through the wiring compartment .
TEKNO POINT ITALIA S.R.L. - VIA DELL'ARTIGIANATO 5 - 30020 MARCON (VE) – ITALY
TEKNO POINT ITALIA S.R.L. - VIA DELL'ARTIGIANATO 5 - 30020 MARCON (VE) – ITALY
COMMERCIALE@TEKNOPOINT.COM – WWW.TEKNOPOINT.COM
COMMERCIALE@TEKNOPOINT.COM – WWW.TEKNOPOINT.COM
MUI_UNITÀ INTERNA DELFIN_Ita_Eng_Fra_Deu_SKY/Rev.00/Data 03.06.2020
MUI_DELFIN_Ita_Eng_Fra_Deu_SKY/Rev.00/Data 03.06.2020
Drain hose
Outlet pipe
Screw
Electric boc cover
Drain hose
Indoor unit connections
47
54
ENGLISH
Drain hose
Tape
Yellow-green
Brown
Blue
Black
67