The earthing resistance must comply with current national electrical safety regulations.
The switch or the power plug of the unit must always be easy to ccessibili by users at the conclusion .
All power and communication cables must be installed by qualified personnel.If the power cable is of
ENGLISH
insufficient length, replace it with one of adequate length. Do not ever joints more cables.
In installations that do not include the power plug , a disconnector installed on the line and a must be
provided .
Indoor units must be securely attached to the wall or ceiling. The block or ceiling to which they are
Moving the air conditioner from one place to another must only be carried out by qualified personnel in
attached must be able to support the load generated by the units.
order not to incur physical injury or damage the units.
Provide always places the installation of the units outside of the reach of children or pets. If it is not
ENGLISH
possible to install the units in safe places, it is necessary to provide safety protection systems (protective
grids or similar) that prevent children or pets from coming into contact with the units .
Indoor units must be securely attached to the wall or ceiling. The block or ceiling to which they are
attached must be able to support the load generated by the units.
TEKNO POINT ITALIA S.R.L. - VIA DELL'ARTIGIANATO 5 - 30020 MARCON (VE) – ITALY

Operating temperatures

Cooling mode max. temperature
Heating mode max.temperature
The operating temperature range (outdoor temperature) for cooling is 18 ℃ ~ 52 ℃ ; The heating
NOTE:
temperature range for the low temperature system model is -15 ℃ ~ 24 ℃ ; The heating temperature
range with low temperature system is -20 ℃ ~ 24 ℃ .

Indoor unit installation

Qualifications required for installation and maintenance
All workers who install refrigeration systems should have valid certification issued by the competent
authority, and qualification for the treatment of the refrigeration system recognized by this sector. If
another technician is needed for the maintenance and repair of the appliance, these must be supervised by
the person who is qualified for the use of the flammable refrigerant.

Installation notes

It is not allowed to use the air conditioner in a room where a fire has occurred.
Drilling holes or burning the connection pipe is not allowed.
The air conditioner must be installed in a room that guarantees the minimum surface. The
minimum surface is shown in table 1
Obligation to check for leaks after installation.
Table 1
Gas
charge
(kg)
Pos.
floor
Minimum area
Pos.
of the room
Window
(m2)
Pos.
TEKNO POINT ITALIA S.R.L. - VIA DELL'ARTIGIANATO 5 - 30020 MARCON (VE) – ITALY
Wall
Pos. on
the
ceiling
48
Notes for maintenance
COMMERCIALE@TEKNOPOINT.COM – WWW.TEKNOPOINT.COM
MUI_DELFIN_Ita_Eng_Fra_Deu_SKY/Rev.00/Data 03.06.2020
<=
1.3
1.4
1.2
/
14.5 16.8 19.3 22.0 24.8 27.8 31.0 34.4 37.8 41.5 45.4 49.4 53.6
/
5.2
6.1
/
1.6
1.9
COMMERCIALE@TEKNOPOINT.COM – WWW.TEKNOPOINT.COM
MUI_UNITÀ INTERNA DELFIN_Ita_Eng_Fra_Deu_SKY/Rev.00/Data 03.06.2020
/
1.1
1.3
41
Indoor
Dry bulb/Wet bulb (°C)
32/23
27/-
1.5
1.6
1.7
1.8
7.0
7.9
8.9
10.0 11.2 12.4 13.6 15
2.1
2.4
2.8
3.1
1.4
1.6
1.8
2.1
42
External
Dry bulb/Wet bulb (°C)
52/26
24/18
1.9
2.0
2.1
2.2
3.4
3.8
4.2
4.6
2.3
2.6
2.8
3.1
ENGLISH
2.3
2.4
2.5
16.3 17.8 19.3
5
5.5
6.0
3.4
3.7
4.0