9.2 WARMER climate
Design capacity (P
)
DESIGN
Nominal energy efficiency (η
SCOP
Data for Packaged Fiche:
Energy efficiency with OTC control (η
Energy efficiency with thermostats (η
Annual energy consumption (Q
9.3 COLDER climate
Design capacity (P
)
DESIGN
Nominal energy efficiency (η
SCOP
Data for Packaged Fiche:
Energy efficiency with OTC control (η
Energy efficiency with thermostats (η
Annual energy consumption (Q
9.4 Additional data
Electrical power input in stand-by mode (Psb)
Electrical power input in thermostat-OFF mode (Pto)
Electrical power input in OFF mode (Poff)
Electrical power input in crankcase heater mode (Pck)
Sound power level of outdoor unit (L
Capacity control mode
Integrated supplementary heater
Nominal outdoor air flow
9.5
General ERP data for hot water storage tanks
Storage volume
Standing loss
Energy efficiency class
PMEN0647 rev.0 - 11/2023
)
S
) (*)
S
) (*)
S
)
HE
)
S
) (*)
S
) (*)
S
)
HE
)
WA
Model
HP
2.0 HP
Outdoor unit
RASM-2VR2E
kW
4.00
%
185 (194)
-
4.69 (4.92)
%
189 (198)
%
192 (202)
kW·h
1139 (1087)
HP
2.0 HP
Outdoor unit
RASM-2VR2E
kW
%
125 (126)
-
3.21 (3.24)
%
125 (127)
%
127 (129)
kW·h
3359 (3333)
HP
2.0 HP
Outdoor unit
RASM-2VR2E
W
W
W
W
dB(A)
-
kW
m
/h
2436
3
DHWT-200S-3.0H2E
L
194
W
47.3
-
B
3.0 HP
RASM-3VR2E
6.00
170 (175)
4.33 (4.46)
173 (178)
177 (182)
1851 (1799)
3.0 HP
RASM-3VR2E
4.00
6.00
113 (113)
2.90 (2.91)
120 (120)
122 (122)
4910 (4884)
3.0 HP
RASM-3VR2E
11.9
11.9
0.0
0.0
11.9
11.9
0.0
0.0
49
57
Variable (Inverter)
No
2682
DHWT-300S-3.0H2E
264
62.8
B
71
9