Jumper
13
14

NOTE
• If wireless intelligent thermostat is selected, optional ON/OFF thermostat has no effect.
• Set the configuration in the user's control.
• In case of setting an installation with 2 circuits (Circuit 1 and Circuit 2) and a different Demand
ON/OFF is used for each of them, please refer to
section in this chapter.
• Auxiliary power supply is available for thermostats and central devices (28 and 29 terminals of TB2).
◆ Unit controller connection
  
In those cases where the unit controller is ordered as a required accessory, or those cases where
another unit controller must be connected as a second thermostat, the connections between unit
controller and the unit must be done in terminals 3 and 4, as it is shown in the next picture:
◆ Earth
  
PMEN0647 rev.0 - 11/2023
13
14
Common
Line
Demand ON/OFF Receiver input 2
Thermostat requirements:
Power supply: 230V AC
Contact voltage: 230V
"6.3.2 Input terminals (Default input functions)"
3
4
A
B
OK
RCS H‑LINK
12
Earth
6
38