3.1 Considerations
Key words:
• U: Voltage.
• IPT: Total input power.
• RNC: Running current.
• MC: Maximum current.

NOTE
• Heating conditions: Inlet/outlet water temperature: 30/35°C; Outdoor ambient temperature
(DB/WB): 7/6°C.
• The compressor data shown in the tables below are based on a combined capacity of 100% of
the power supplied.
• The "Maximum current" shown in the below table is the maximum total unit running current at
the following conditions:
9 Supply voltage: 90% of the rated voltage.
9 Unit capacity: 100% at maximum operating conditions.
• The power supply cables must be sized to cover this maximum current value.
• Specifications in these tables are subject to change without notice in order that Hitachi may
bring the latest innovations to their customers.
• Please refer to the general information, cautions and notes regarding protective devices (CB, ELB)
throughout the
"Electrical and control settings"
3.1.1 Monobloc system - YUTAKI M - RASM-(2/3)VR2E
Model
Power supply
RASM-
2VR2E
~ 230V 50Hz
RASM-
3VR2E

NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot
water tank accessory "DHWT‑(200/300)S‑3.0H2E".
PMEN0647 rev.0 - 11/2023
Applicable
voltage
Operation mode
U max
U min
(V)
(V)
Without DHW tank heater
With DHW tank heater
253
207
Without DHW tank heater
With DHW tank heater
chapter.
Cooling
operation
RNC
IPT
(A)
(KW)
6.3
1.3
6.3
1.3
11.2
2.33
11.2
2.33
Heating
Max
operation
MC
IPT
(A)
(kW)
RNC
IPT
(A)
(KW)
4.1
0.86
12.8
2.32
16.5
3.61
24.7
5.07
7.7
1.59
16.8
3.06
20
4.34
28.7
5.81
9
3