10.11. Activating standby for remote operation

EN 60335-2-53 specifies that sauna control units with a remote start function
must be set manually to "Standby for remote operation" mode.
This activation must take place again after each remote start and stop
procedure.
With safety shut-off activated (standard)
Perform the following steps:
1. Turn the function selector 2 to position J (remote start).
► "oFF" appears in the intensity display 4.
2. Press the bottom knob to activate "Standby for remote operation" mode.
► "on" appears in the intensity display 4 and the remote start symbol
starts flashing.
► The sauna control unit is then ready to be started and stopped using a
remote start signal.
► After a remote start and stop, the remote start icon goes out and the
mode has to be activated again.
When the door sensor is activated
Perform the following steps:
1. Turn the function selector 2 to position J (remote start).
► "oFF" appears in the intensity display 4.
2. Press the bottom knob to activate "Standby for remote operation" mode.
► A countdown of 30 seconds is displayed in the display 4. The door can
be opened and closed as many times as desired during this time. After
the countdown has elapsed, the door must be closed!
► "rc" appears in the intensity display 4 and the remote start symbol
starts flashing.
► The sauna control unit is now ready to be started using a remote start
signal (= "Standby for remote operation" mode)
► After a remote start and stop, the remote start icon goes out and the
mode has to be activated again.