5.3.3
Gerätespezifische Parameter
Index
sub Name
hex
0x3C
0x01 BD1.SP1
0x02 BD1.SP2
0x3D
0x01 Switch point
0x02 Switch point
0x03 Switch point
0x3E
0x01 SP1 (set point 1)
0x02 SP2 (set point 2)
0x3F
0x01 Switch point
0x02 Switch point
0x03 Switch point Hys-
Type
BD1 - Set
Point Value
(BD1.SPV)
R/W
(set point 1)
R/W
(set point 2)
BD1 - Switch
Point Confi-
guration
(BD1.SPC)
R/W
Logic
R/W
Mode
R/W
Hysteresis
BD2 - Set
Point Value
(BD2.SPV)
R/W
R/W
BD2 - Switch
Point Confi-
guration
(BD2.SPC)
R/W
Logic
R/W
Mode
R/W
teresis
UC***-30GM-**EP-IO-V15
Data
Value
type
record
uint16
35 - 1000
80 - 4000
200 - 8000
350 - 10000
uint16
35 - 1000
80 - 4000
200 - 8000
350 - 10000
record
uint8
0x00 - Non Inverted
0x01- Inverted
uint8
0x01 - Single Point Mode
0x02 - Window Mode
0x03 - Two Point Mode
0x80 - Barrier Mode
uint16
0 ... 50
record
uint16
35 - 1000
80 - 4000
200 - 8000
350 - 10000
uint16
35 - 1000
80 - 4000
200 - 8000
350 - 10000
record
uint8
0x00 - Non Inverted
0x01- Inverted
uint8
0x01 - Single Point Mode
0x02 - Window Mode
0x03 - Two Point Mode
0x80 - Barrier Mode
uint16
0 ... 50
IO-Link
Default Unit
50
mm
100
240
400
500
mm
2000
4000
6000
0x00
0x01
1
%
100
mm
100
500
500
250
mm
1000
2000
3000
0x00
0x01
1
%
31