ABB FCM2000 Inbetriebnahmeanleitung Seite 52

Vorschau ausblenden Andere Handbücher für FCM2000:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation
Pos: 19.5 /Standard-Layout/Ex-relevante Technische Daten/Durchfluss/FCM2000/Version III: Feldbuskommunikation @ 49\mod_1309180277243_3101.doc @ 406267 @ @ 1
Version III: Fieldbus communication
Types ME21/ME22/ME23/ME24/ME25/ME26/ME27/ME28 and MC23/MC27
Fieldbus
Passive
Terminals 97/98
The output and supply power are electrically isolated.
Types ME26/ME27/ME28 and MC27
"e" (Zone 1)
U
(V)
Fieldbus
Passive
60
Terminals 97/98
The output and supply power are electrically isolated.
Pos: 19.6 /Standard-Layout/==== Wechsel ein- auf zweispaltig ==== @ 0\mod_1130421847171_3101.doc @ 3828 @ @ 1
Change from one to two columns
Pos: 19.7 /Standard-Layout/Ex-relevante Technische Daten/Durchfluss/FCM2000/Besondere Bedingungen @ 22\mod_1219323289546_3101.doc @ 209963 @ 5 @ 1
Special conditions
The output circuits are designed in such a way that they can be
connected to both intrinsically-safe and non-intrinsically-safe circuits.
It is not permitted to combine intrinsically safe and non-intrinsically
safe circuits. On intrinsically safe circuits, equipotential bonding must
be in place along the entire length of the cable used for the current
outputs. The rated voltage of the non-intrinsically safe circuits
is U M = 60 V.
Change from one to two columns
Pos: 19.9 /Standard-Layout/Ex-relevante Technische Daten/Durchfluss/FCM2000/Hinweis Schutzleiter @ 22\mod_1219387431843_3101.doc @ 210003 @ @ 1
Important
If the protective conductor (PE) is connected in the flowmeter's terminal box, you must ensure that no dangerous
potential difference can arise between the protective conductor (PE) and the equipotential bonding (PA) in the
potentially explosive area.
Pos: 19.10 /Standard-Layout/======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ @ 1
18 - EN
Protection type "nL"
(Zone 2)
U
I
(V)
(mA)
60
500
Type of
General
protection
operating
values
I
U
I
b
b
(A)
(V)
(mA)
35
32
10
CoriolisMaster FCM2000
General
operating values
U
I
b
b
(V)
(mA)
(V)
32
10
60
Protection type
"ia" FISCO (Zone 1)
U
I
P
C
C
i
i
i
i
i
(V)
(mA)
(mW)
(nF)
(nF)
60
380
5320
0
The contact output and the pulse output (terminals 41 / 42 and 51 /
52) can be wired internally as a NAMUR contact for the purpose of
connecting a NAMUR amplifier.
The cable glands are supplied in black by default. If the signal outputs
are wired to intrinsically safe circuits, we recommend that you use the
light blue caps supplied for the appropriate cable entries.
Pos: 19.8 /Standard-Layout/==== Wechsel zwei- auf einspaltig ==== @ 0\mod_1130421955859_3101.doc @ 3829 @ @ 1
Protection type "n"
FNICO (Zone 2)
U
I
P
C
i
i
i
(mA)
(mW)
(nF)
500
7,000
Protection type
"ia" (Zone 1)
pa
L
U
I
P
i
i
i
(mH)
(V)
(mA)
(mW)
0
0.17
60
380
5320
C
pa
L
i
i
i
(nF)
(mH)
0
0
0.17
C
C
pa
L
i
i
i
i
(nF)
(nF)
(mH)
0
0
0.17
CI/FCM2000-EN