Installation
Pos: 14.8 /Standard-Layout/Überschriften/1.1.1/1-spaltig/Elektrische Anschlüsse Messumformer an Peripherie @ 26\mod_1234873728156_3101.doc @ 246204 @ 3 @ 1
4.1.2
Electrical connections between the transmitter and the peripherals
Pos: 14.9 /Standard-Layout/Technische Daten / Datenblatt/Durchfluss/FCM2000/Elektrischer Anschluss/Ein- / Ausgangssignale ME2 / MC2_ohne FM @ 49\mod_1311942843900_3101.doc @ 416748 @ 5 @ 1
Input and output signals, supply power ME2/MC2
1+
2-
L
N
1
51 52 81 82 41 42 31 32 33 34
4
Fig. 6
1 Supply power
Line voltage: U
100 ... 230 V AC, frequency 50/60 Hz,
AC
terminals L, N,
Low voltage: U
24 V, frequency 50/60 Hz, terminals 1+, 2-
AC
Low voltage:
U
24 V
DC
2 Current output 1: can be selected via software
2a: function: active
Terminals: 31, 32; 0/4 ... 20 mA (0 Ω ≤ R
MC27/ME26: 0 Ω <= RB <= 300 Ω)
2b: alternate function: passive (option D)
Terminals: 31, 32; 4 ... 20 mA (0 Ω ≤ R
Source voltage 12 ≤ U
≤ 30 V
q
3 Current output 2: can be selected via software
Function: passive
Terminals: 33, 34; 4 ... 20 mA (0 Ω ≤ R
Source voltage 12 ≤ U
≤ 30 V
q
Important
You can find the applicable Ex-relevant connection data in the section titled "Ex relevant specifications".
Pos: 14.10 /Standard-Layout/======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @ @ 1
12 - EN
31 32 33 34 51 52 41 42 81 82
2
3
4
5
5
6
2
3
≤ 560 Ω,
B
≤ 600 Ω)
B
≤ 600 Ω)
B
CoriolisMaster FCM2000
7
7
6
7
7
7
2-
1+
N
L
7
1
7
4a Passive pulse output, terminals: 51, 52
f
= 5 kHz, pulse width 0.1 ... 2,000 ms
max
Setting range: 0.001 ... 1,000 pulses/unit
"Closed": 0 V ≤ U
"Open": 16 V ≤ U
4b Active pulse output
U = 16 ... 30 V, load ≥ 150 Ω, f
5 Contact output, passive
Terminals: 41, 42
"Closed": 0 V ≤ U
"Open": 16 V ≤ U
6 Contact input, passive
Terminals: 81, 82
"On": 16 V ≤ U
"Off": 0 V ≤ U
7 Equipotential bonding "PA" (when connecting transmitter ME2
to flowmeter sensor MC26, transmitter ME2 also has to be
connected to "PA").
MC23
MC27
ME26
MC26
ME21
7
MC21
≤ 2 V, 2 mA ≤ I
≤ 65 mA
CEL
CEL
≤ 30 V, 0 mA ≤ I
≤ 0.2 mA
CEH
CEH
= 5 kHz, 
max
≤ 2 V, 2 mA ≤ I
≤ 65 mA
CEL
CEL
≤ 30 V, 0 mA ≤ I
≤ 0.2 mA
CEH
CEH
≤ 30 V
KL
≤ 2 V
KL