Using the power supply

6.11 Activating the menu

The main menu is accessed with the MENU button and
the display changes to the main menu level. A text menu like
this appears:
Profile
Setting up and selecting user profiles
Function
Setting up a function sequence
Analog interface
Settings for the internal analog
interface
Communication
Configure the dig. interface card
Options
Default setup, unlock features,
Lock device configuration
About...
Manufacturer, Service, SW version etc.
A menu page is left to the next higher level by pressing
the ESC button.
The SELECT keys are used to select another
menu entry.
The RETURN button then enters the menu entry into the
next sublevel by pressing it. The lowest menu level always shows
up as a parameter page. See next topic for details.
Error type
OV
SYS
FCT
OT
CAN
U>
def. def. def.
U<
def. def. def.
I>
def. def. def.
I<
def. def. def.
U
def. def. def.
U
def. def. def.
I
def. def. def.
I
def. def. def.
P
def. def. def.
P
def. def. def.
1)
OT disappear = OFF
2)
OT disappear = auto ON
def. = definable
Operating Guide
PSI 8000 T Series
Description
Overvoltage at the power output
General system error
Function could not be saved and/or submitted
1)
Overtemperature error
2)
CAN bus transmission error
Overvoltage supervision threshold exceeded
Undervoltage supervision threshold exceeded
Overcurrent supervision threshold exceeded
Undercurrent supervision threshold exceeded
Set-actual comparison error at a positive voltage transition
Set-actual comparison error at a negative voltage transition
Set-actual comparison error at a positive current transition
Set-actual comparison error at a negative current transition
Set-actual comparison error at a positive power transition
Set-actual comparison error at a negative power transition
6.12 Parameter pages
The parameter page is the lowest menu level. Here you can
change many different parameters in order to set up the device.
By pressing the ESC button the parameter page is left to
the next higher level and no parameters are accepted.
The SELECT keys are used to select a different
parameter. The selected parameter is then displayed inverted
and can be changed with the left rotary knob.
The RETURN button submits the changed parameters,
which are accepted and stored and used. The parameter page
is also exited to the next higher level.

6.13 Alarms, warnings and signals

Alarms, warnings and simple notifications (here called „signals")
can be acoustically signalled or optically in the display (see sec-
tion „7.4 Configuring the control panel").
An alarm has a higher priority than a warning or signal. Up to four
alarms, warnings or signals can be displayed, which will cycle in
an interval of two seconds. If an alarm occurs, one previous warn-
ing or signal will be suppressed if the total number exceeds four.
The power supply monitors the interface cards for transmission
errors as well user-defined warnings and alarms.
The output voltage, the output current and the difference between
actual and set value can be monitored.
The table below gives an overview of the possible errors and
their meanings, as well as the selectable error types, as far as
these are configurable.
Date: 02-05-2016
EN
47