About the power supply
3.

Device description

3.1

Front view / front panel

Description of the knobs, buttons and terminals:
1)
Power output, safety sockets, poled
The sockets can be used to plug 4 mm plugs or to clamp
spade lugs.
2)
Remote sense input, poled
The remote sense cables are connected here with correct
polarity. For details about the remote sense feature refer to
section „10.1 Remote sense".
3)
Analog interface, 15pole, D-Sub, female
The socket can be used to remotely control and monitor the
device by means of analog resp. digital signals. For more
information refer to section „9. Internal analog interface".
4)
Pushbutton „Standby"
Is used to switch the device into standby and back to normal
operation.
5)
Rotary encoder, right, no stop
Is used to adjust the set value of the output current, the output
power (models from 1 kW) or the internal resistance (op-
tional, only models with unlocked internal resistance control).
Approximately 5 complete turns correspond to 0...100%.
In the setup, it is used to adjust settings.
Also see sections „6.6 Adjusting set values" and „7. Device
configuration".
6)
Rotary encoder, left, no stop
Is used to adjust the set value for the output voltage.
Approximately 5 complete turns correspond to 0...100%.
In the setup, it is used to select parameters.
Also see sections „6.6 Adjusting set values" and „7. Device
configuration".
7)
Control panel and display unit