9. Take off the device cover (3 quick fasteners) and close the
high-pressure output with the protective part intended for it.
Lock
1
Water inlet for high-pressure pump
2
Water inlet from water reservoir
3
Fixing the water supply hose
4
10.Disconnect the water inlet at the GEKA connection.
11.Close the water inlet for the high-pressure pump.
12.Fix (store) the water supply hose of the water reservoir under
the waste container.
Care and service
Each time before use
1. Check all hydraulic hoses and connections for leaks.
2. Check the high-pressure hose for damage (danger of burst-
ing).
Immediately replace a damaged high-pressure hose.
3. Check the device (pump) for leaks.
3 drops of water per minute are permissible and can leak out
of the bottom of the appliance. Contact Customer Service in
the case of more serious leaks.
Weekly
Note
To read the oil level or clean the water screen, remove the device
cover (3 quick fasteners).
1. Read the oil level when the device is on a flat surface. The oil
level must be in the middle of the sight glass.
Contact Customer Service immediately if the oil is milky (water
in oil).
2. Clean the sieve in the water connection.
3. Depressurise the device.
4. Unscrew the cover with filter.
5. Clean the filter with clean water or compressed air.
Assemble in the reverse order.
Annually or after 500 operating hours
1. Changing oil.
For oil quantity and type, see Technical data.
2. Have the oil changed by Customer Service.

Frost protection

ATTENTION
Danger of frost
Incompletely emptied devices can be destroyed by frost.
Completely empty the device and accessories.
Protect the device from frost.
1. Store the device in a frost-protected place.
Note
If frost-free storage is not possible:
2. Close off the water inlet.
3. Allow the device for run for a maximum of 1 minute until the
pump and lines are empty.
4. Blow the high-pressure pump, supply hose, water filter and
high-pressure hose out with compressed air.
DANGER
Risk of injury due to inadvertently starting up device and al-
so due to electric shock.
Switch off the device and remove the ignition key before perform-
ing any work.
Have electrical components checked and repaired by the author-
ised Customer Service.
In case of any malfunctions not mentioned in this chapter, contact
the authorised Customer Service when in doubt or when you
have been explicitly advised to do so.
Device not running
1. Switch on the work hydraulics and high-pressure switch.
Device does not reach required pressure
1. Fill the water reservoir.
2. Clean the water inlet sieve, check the water supply.
3. Check/replace the high-pressure nozzle.
Pump leaking
Up to 3 drops of water per minute are permissible.
 In case of more serious leaks, have the device checked by
Customer Service.
Pump knocking
 Check the water supply line for leaks.
 Vent the device, see section "Venting the device".
 Contact Customer Service if necessary.

Hydraulic connection

Supply from the hydraulic system of the MC 130
Connection output
Water connection
Water supply from the water reservoir of the MC 130
Input temperature (max.)
Performance data
Working pressure
Nozzle size
Max. operating pressure
Flow rate
Recoil force of the trigger gun. (max.)
Determined values in acc. with EN 60335-2-79
Sound pressure level L
K uncertainty
pA
Sound power level L
Hand-arm vibration value
K uncertainty
Operating materials
Oil volume
Oil type
Dimensions and weights
Weight
English
Troubleshooting guide
Technical data
kW
°C
MPa
MPa
l/min
N
dB(A)
pA
dB(A)
+ K uncertainty
dB(A)
WA
WA
2
m/s
2
m/s
l
kg
4.5
60
7-15
036
19
10
30
75
3
97
1.6
0.7
0.4
SAE 15W-40