Signal-Contact Monitor Ring-Redundancy; Signal-Contact Monitor Power-Supply - Hirschmann Hios-2S Rspl Referenzhandbuch

Command line interface (cli) (rail switch power lite)
Inhaltsverzeichnis
Signal Contact

50.1.6 signal-contact monitor ring-redundancy

Sets the monitoring of the ring-redundancy.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor ring-redundancy
Parameter Value
signal contact no.
P-1
no signal-contact monitor ring-redundancy
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor ring-redun-
dancy

50.1.7 signal-contact monitor power-supply

Sets the monitoring of the power supply(s).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor power-supply <P-2>
Parameter Value
signal contact no.
P-1
1..2
P-2
RM CLI HiOS-2S RSPL
Release 5.0 05/2015
Meaning
Meaning
Number of power supply.
50.1 signal-contact
545