Herunterladen Inhalt Inhalt Diese Seite drucken

Cli; Cli Serial-Timeout; Cli Prompt - Hirschmann Hios-2S Rspl Referenzhandbuch

Command line interface (cli) (rail switch power lite)
Inhaltsverzeichnis
Command Line Interface (CLI)

7.1 cli

Set the CLI preferences.
7.1.1

cli serial-timeout

Set login timeout for serial line connection to CLI. Setting to 0 will disable the
timeout. The value is active after next login.
Mode: Privileged Exec Mode
Privilege Level: Operator
Format: cli serial-timeout <P-1>
Parameter Value
0..160
P-1
7.1.2

cli prompt

Change the system prompt. Following wildcards are allowed:
%d date, %t time, %i IP address, %m MAC address ,%p product name
Mode: Privileged Exec Mode
Privilege Level: Operator
Format: cli prompt <P-1>
Parameter Value
string
P-1
126
Meaning
Enter a number in the given range. Setting
to 0 will disable the timeout.
Meaning
Enter a user-defined text, max. 128 charac-
ters. Following wildcards are allowed: %d
date, %t time, %i IP address, %m MAC address
,%p product name
7.1 cli
RM CLI HiOS-2S RSPL
Release 5.0 05/2015
Inhaltsverzeichnis
loading

Inhaltsverzeichnis