Herunterladen Inhalt Inhalt Diese Seite drucken

Port-Monitor; Port-Monitor Condition Crc-Fragments Interval; Port-Monitor Condition Crc-Fragments Count - Hirschmann Hios-2S Rspl Referenzhandbuch

Command line interface (cli) (rail switch power lite)
Inhaltsverzeichnis
Port Monitor

42.2 port-monitor

Configure the Port Monitor condition settings.
42.2.1 port-monitor condition crc-fragments inter-
val
Configure the measure interval in seconds (5-180s) for CRC-Fragment de-
tection. Default 10.
Mode: Interface Range Mode
Privilege Level: Operator
Format: port-monitor condition crc-fragments interval
<P-1>
Parameter Value
5..180
P-1

42.2.2 port-monitor condition crc-fragments count

Configure the CRC-Fragment counter in parts per million (1-1000000 [ppm]).
Default 1000 [ppm].
Mode: Interface Range Mode
Privilege Level: Operator
Format: port-monitor condition crc-fragments count <P-1>
Parameter Value
1..1000000
P-1
RM CLI HiOS-2S RSPL
Release 5.0 05/2015
Meaning
Enter a number in the given range.
Meaning
Enter a number in the given range.
42.2 port-monitor