Device Security
no security-status monitor pwd-min-length
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no security-status monitor pwd-min-length
12.1.3 security-status monitor pwd-policy-config
Sets the monitoring whether the minimum password policy is configured. The
device changes the security status to the value "error" if the value for at least
one of the following password rules is 0:\n"minimum upper cases","minimum
lower cases","minimum numbers","minimum special characters".
Mode: Global Config Mode
Privilege Level: Administrator
Format: security-status monitor pwd-policy-config
no security-status monitor pwd-policy-config
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no security-status monitor pwd-policy-config
RM CLI HiOS-2S RSPL
Release 5.0 05/2015
12.1 security-status
181