Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been improp-
erly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the wall
outlet
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 square millimetres.
Connection type X
If the mains connection cable of this device is dam-
aged, it must be replaced by a special connection ca-
ble which can be obtained from the manufacturer or its
service department.

12. Cleaning, maintenance and storage

m Attention!
Pull out the mains plug before carrying out any clean-
ing and maintenance work! Risk of injury from electric
shock!
30 | GB
m Attention!
Wait until the equipment has cooled down completely!
Danger of burning!
m Attention!
Always depressurise the equipment before carrying
out any cleaning and maintenance work! Risk of injury!
12.1 Cleaning
• Keep the device as free of dust and dirt as possible.
Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
• The hose and injection tools must be disconnect-
ed from the compressor before cleaning. The com-
pressor must not be cleaned with water, solvents
or similar.
12.2 Pressure vessel maintenance /
Condensate (Fig. 1)
m Attention!
To ensure a long service life for the pressure ves-
sel (6), drain off the condensate after each use by
opening the drain screw (8).
Release the vessel pressure beforehand (see 12.7.1).
The drain screw is opened by turning it counterclock-
wise (when looking at the screw on the bottom of the
compressor) so that the condensate can be complete-
ly drained out of the pressure vessel. Then close the
drain screw again (turn clockwise). Check the pres-
sure vessel for rust and damage each time before use.
The compressor shall not be operated if the pressure
vessel is damaged or rusty.
If you discover damage, please contact the customer
service workshop.
12.3 Safety valve (Fig. 2)
The safety valve (14) is set to the maximum permissible
pressure of the pressure vessel. It is not permitted to
adjust the safety valve or remove the connection lock
(14.2) between the exhaust nut (14.1) and its cap (14.3).