11. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
When working with spray attachments and during
temporary use outdoors, the device must be connected
to a residual current circuit breaker with a trigger
current of 30 mA or less.
Damaged electrical connection cable.
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been
improperly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the wall
outlet
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly.
Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with
the applicable VDE and DIN provisions. Only use
connection cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a cross-
section of 1.5 square millimetres.
Connections and repair work on the electrical
equipment may only be carried out by electricians.
Please provide the following information in the
event of any enquiries:
26 | GB
• Type of current for the motor
• Data of machine type plate
• Data of motor type plate

12. Cleaning, maintenance and storage

m ATTENTION!
Pull out the mains plug before carrying out any
cleaning and maintenance work! Risk of injury from
electric shock!
m ATTENTION!
Wait until the equipment has cooled down completely!
Danger of burning!
m ATTENTION!
Always depressurise the equipment before carrying
out any cleaning and maintenance work! Risk of injury!
12.1 Cleaning
• Keep the device as free of dust and dirt as possible.
Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
• The hose and injection tools must be disconnected
from
compressor must not be cleaned with water,
solvents or similar.
12.2 Pressure
Condensate (Fig. 1)
m ATTENTION!
To ensure a long service life for the pressure
vessel (4), drain off the condensate after each use
by opening the drain screw (11).
Release
10.4.1). The drain screw is opened by turning it
counterclockwise (when looking at the screw on the
bottom of the compressor) so that the condensate can
be completely drained out of the pressure vessel.
Then close the drain screw again (turn clockwise).
Check the pressure vessel for rust and damage each
time before use.
The compressor shall not be operated if the pressure
vessel is damaged or rusty.
www.scheppach.com
the
compressor
before
vessel
maintenance
the
vessel
pressure
cleaning.