11. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the extension
cable used must also comply with these regula-
tions.
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Damaged electrical connection cable.
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been improp-
erly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the wall
outlet
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly.
Ensure that the connection cables are disconnect-
ed from electrical power when checking for damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 square millimetres.
26 | GB
Connection type X
If the mains connection cable of this device is dam-
aged, it must be replaced with a special connection
lead available from the manufacturer or its after-sales
service.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Data of machine type plate
• Data of motor type plate

12. Cleaning, maintenance and storage

m ATTENTION!
Pull out the mains plug before carrying out any clean-
ing and maintenance work! Risk of injury from electric
shock!
m ATTENTION!
Wait until the equipment has cooled down completely!
Danger of burning!
m ATTENTION!
Always depressurise the equipment before carrying
out any cleaning and maintenance work! Risk of injury!
12.1 Cleaning
• Keep the device as free of dust and dirt as possible.
Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
• The hose and injection tools must be disconnected
from the compressor before cleaning. The com-
pressor must not be cleaned with water, solvents or
similar.