Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH

USE

WARNING!
On some points of the machine there are some adhesive plates indicating:
DANGER
WARNING
CAUTION
CONSULTATION
While reading this Manual, the operator must pay particular attention to the symbols shown on the plates (see the Visible Symbols
On The Machine paragraph).
Do not cover these plates for any reason and immediately replace them if they are damaged.
If the machine has not been used after being transported, check that all the blocks have been removed.

FUEL

DANGER!
Fuel for Diesel version
CAUTION!
Always stop the engine before filling the fuel tank.
Do not smoke while filling the fuel tank.
Fill the fuel tank in a well-ventilated area.
Do not fill the fuel tank near sparks or open flame.
1.
Open the engine compartment hood (19) and check that it is fastened with the support rod (47).
2.
Unscrew the plug (45) of the fuel tank (44) and refuel. Do not overfill and wipe any fuel accidentally spilled out.
3.
Never not use old or contaminated diesel fuel, and prevent dirt or water from entering the fuel tank.
Supply for LPG version
DANGER!
Before replacing the LPG tank, close the safety valve and disconnect the hose.
1.
Install an LPG tank (34) having characteristics which comply with the laws in force in the country where it is used.
2.
Fasten the tank with a fastening band (35).
3.
Connect the hose and open the cut-off valve on the LPG tank. Always wear gloves when connecting and disconnecting the
hose. When the machine is not operating, close the LPG tank cutoff valve.
NOTE
Place the LPG tank in a proper horizontal position. Connect the hose to the tank and check that there are no gas leaks.
DANGER!
Do not use the machine in case of gas leaks. Disconnect the hose and replace the LPG tank. If the gas leak
persists, disconnect the hose and contact the Nilfisk Service Center.
18
All manuals and user guides at all-guides.com
INSTRUCTIONS FOR USE
Carbon monoxide (CO) can cause brain damage or death.
The internal combustion engine of this machine can emit carbon monoxide.
Do not inhale exhaust gas fumes.
Only use indoors when adequate ventilation is provided, and with the help
of an assistant.
SW5500, FLOORTEC R 985 - 1466472000
03/2016

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Floortec r 985

Inhaltsverzeichnis