Herunterladen Inhalt Inhalt Diese Seite drucken

Drilling; Removing The Drill Chuck From The Spindle Holding Fixture - Optimum Optidrill DX 13V Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Optidrill DX 13V:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.5

Drilling

Switch on the master switch.
Insert and tighten the drill bit.
Clamp the workpiece.
Unlock the emergency-stop.
Close drill chuck protection.
Push Start.
If necessary, change the preset speed with the rotary knob.
Press Stop.
INFORMATION
For a long-term standstill of the machine switch it off at the main switch.
4.6

Removing the drill chuck from the spindle holding fixture

DX13V with B16 spindle
A friction-locking connector holds and centres the drill chuck in the B16 holding fixture.
Rotate the nut downwards; the drill chuck is pushed out of the chuck cone. If necessary,
exert counter pressure on the drill chuck.
INFORMATION
If the nut is no longer available, you can use, for example, an aluminium wedge or other
appropriate lever to remove the drill chuck from the spindle holding fixture.
Img.4-2:
Nut for loosening the connection DX13V
The drill chuck and the taper mandrel are loosened from the drill spindle by means of a drill
drift.
WARNING!
Only disassemble the drill chuck if the drilling machine is disconnected from the
electrical supply.
EN
DX13V | DX15V
54
Nut
Originalbetriebsanleitung
Operation
Version 1.0.4 - 2021-08-30

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Optidrill dx 15v302 0150302 0155

Inhaltsverzeichnis