SAFETY SUMMARY

1 SAFETY SUMMARY
HITACHI cannot anticipate every possible circumstance that
might involve a potential hazard.
!
D A N G E R
DO NOT pour water into the remote controller. This product is
equipped with electrical parts. If poured, it will cause a serious
electrical shock.
DO NOT perform installation work and electrical wiring
connection by yourself. Contact your HITACHI distributor or
dealer and ask them for installation work and electrical wiring
by service person.
!
C A U T I O N
DO NOT install the indoor unit, outdoor unit, controller and cable at
such places as:
- Where there is oil vapor and the oil is dispersed.
- Where the hot springs are near (in a sulfuric environment).
- W here generation, flowing, staying or leaking of flammable gas is
detected.
- Where the sea is near (in the salty environment).
- An acid or alkaline environment.
DO NOT install the indoor unit, outdoor unit, controller and cable
within approximately 3 meters from strong electro m agnetic wave
radiators such as medical equipment. In case that the controller is
installed in a place where there is electromagnetic wave radiation,
shield the controller and cables by covering with the steel box and
running the cable through the metal conduit tube.
In case that there is electric noise at the power source for the indoor
unit, provide a noise filter.
Use specified cables to connect between indoor unit and remote
control switch. Selecting incorrect cables may lead to fire or electrical
shock.
?
N O T E
The installer and system specialist shall comply with local regulations
or standards for the safety. The following standards may be applicable,
if local regulations are not available. International Organization for
Standardization, ISO5149 or European Standard, EN378 or Japan
Standard, KHKS0010.
Perform electrical work according to the Installation Manual. As for
the electrical wiring work and check, turn OFF the main power supply
before opening/closing the service cover of indoor unit. If service
cover is opened with main power supply left on, it may result in an
electrical shock.
It is assumed that this control remote will be operated and serviced by
English speaking people. If this is not the case, the customer should
add safety such as and operating signs in the native language for non
English speakers.
This manual should be considered as a permanent part of the air
conditioning equipment and should remain with the air conditioning
equipment.
This appliance must be used only by adult and capable people,
having received the technical information or instructions to handle
this appliance properly and safely.
Children should be supervised to ensure that they do not play with
the appliance.
Important: read and understand this manual before using this remote
controller.
If you have any questions, contact your HITACHI distributor or
dealer.
2 BEFORE INSTALLATION AND
OPERATION
The packing contains the following parts. Check the contents
and the number of the parts.
1
PMML0414A rev.5 - 06/2019 - P5416676
Name
Wireless remote control switch
(controller)
Holding bracket
Batery (AAA/1.5 dry cell)
Screw
Installation and operation manual

3 SETTING BATTERIES

Set the batteries (AAA/1.5Vx2) for the controller as follows.
1 Remove the battery cover by sliding toward the arrow
direction by pushing the part of the cover as shown in the
figure below.
2 Set the batteries. (Insert the batteries according to the marks
of + and - on the case.)
!
C A U T I O N
Do not press the "
On" and "On Timer" switches until the preparation
for Test Run is completed.
Slide the battery
cover toward the
arrow direction
Battery cover

4 NAME OF PARTS

This controller is used to send commands about operation
mode, timer setting, etc. to the indoor unit. Face the
transmitter of the controller toward the receiver of the indoor
unit and press the switch of required operation so that
commands (by infrared rays) are sent to the indoor unit.
The distance for transmitting is approximately 6 meters as
a maximum. (The capable distance for transmitting will get
shorter in case that the transmitting angle is not vertical to
the receiver or an electronic type light is used in the room,
etc.).
Use the combination of the receiver kit and the indoor unit
which are supported by this controller.
Reset switch
Transmitter
Point the transmitter towards the receiver of the indoor unit when
sending commands. The transmitting indication on the liquid crystal
display flashes when sending commands.
Transmitting indication: It will turn ON when sending commands by
infrared rays.
Liquid crystal display
The set temperature, timer operation, position of air louver,
operation mode, air flow mode, etc., are indicated. The diagram of
the display shown left is for explanation purposes only. The display
will differ during actual operation.
Fan speed switch
Press this switch to select the fan speed. By repeatedly pressing
Qty
Remark
1
For operation control
1
For controller
2
For power source of controller
For fixing "Holding bracket"
2
onto wall
1
with pushing
AAA Bateries