LCD (Liquid Crystal Display)
The set temperature, timer operation, position of air louver, operation mode,
air flow mode, etc., are indicated.
NOTE:
The diagram of the display shown on the left is for explanation purposes only.
The display will differ during actual operation.

SENDING COMMANDS FROM CONTROLLER

Fan Speed Switch
Press this switch to select the fan speed. By repeatedly pressing the switch,
the button, the setting will change sequentially through LOW, MED,
the setting will change sequentially through LOW, MED, HIGH, HIGH2 and AUTO.
HIGH, HIGH2 and AUTO *.
* Depending on the setting for selecting the function, it is possible to set the
LOW
MED
ON/OFF for the Fan Speed AUTO.
LOW → MED → HIGH → HIGH2 → AUTO
On switch
On Switch
Operation of the unit can be started by pressing this switch.
Operation of the unit can be started by pressing this switch.
Off switch
Off Switch
Operation of the unit can be stopped by pressing this switch.
Operation of the unit can be stopped by pressing this switch.
Mode Selection Switch
Mode Selection Switch
By repeatedly pressing the mode switch, the unit cycles through
By repeatedly pressing the mode switch, the unit cycles through
the different operating modes in the order of FAN, COOL, HEAT,
the different operating modes in the order of FAN, COOL, HEAT, DRY, AUTO.
DRY, AUTO. Depending on the setting for selecting the function, it is
* Depending on the setting for selecting the function, it is possible to set
possible to set the ON/OFF for AUTO, HEAT and DRY display.
the ON/OFF for AUTO, HEAT and DRY display.
FAN,
COOL,
Louver Angle Switch
Louver angle switch
The airflow angle and auto-louver operation can be set by this switch.
The airflow angle and auto-louver operation can be set by this
When pressing the switch, the angle is changed in the following order.
switch. When pressing the switch, the angle is changed in the
(In COOL or DRY or AUTO operation modes, steps 1-5 and Auto swing are
following order. (In COOL or DRY or AUTO operation modes, steps
available.)
1-5 and Auto swing are available.)
1 Step
2 Step
3 Step
1 step
2 step
3 step
4 step
Filter Sign Reset Switch
Filter sign reset switch
When it is time to perform the filter cleaning, the filter indicator lamp will be
turned ON so turn is OFF.
This switch is used to turn off the filter indication lamp of the indoor
The alarm sound can be cancelled temporarily by pressing the switch.
unit, which is turned on when it is required to clean the filter. The
alarm sound can be cancelled temporarily by pressing the button.
Temp. Switch
Temperature switch
The setting temperature can be adjusted using this switch.
By "
" pressing, the temperature will increase by 1°C (or 0.5°C*) at a time.
The setting temperature can be adjusted using this switch.
By "
" pressing, the temperature will decrease by 1°C (or 0.5°C*) at a time.
By pressing "▲", the temperature will increase by 1ºC (or 0.5ºC*) at
NOTE:
a time.
Depending on the setting for selecting the function, it is possible to set
the unit 1
C (or 0.5
C*) for the temperature range.
o
o
By pressing "▼", the temperature will decrease by 1ºC (or 0.5ºC*)
* Only available for the combination of the indoor unit and receiver kit with
at a time.
the function "0.5
C increment".
o
?
N O T E
Timer Switches
Used to set the timer.
Depending on the setting for selecting the function, it is possible to
The set time can be changed by pressing "On Timer" or "Off Timer".
set the unit 1ºC (or 0.5ºC*) for the temperature range.
The timer can be set from 0.5 to 23 hours. When 0.5 to 9.5 hours, the unit will
Timer switches
set as 30 min. at a time, and when 10 to 23 hours, the unit will be set as 1 hour
at a time.
Used to set the timer.
The set time can be changed by pressing "On timer" or "Off timer".
The timer can be set from 0.5 to 23 hours. When 0.5 to 9.5 hours,
the unit will set as 30 min. at a time, and when 10 to 23 hours, the
unit will be set as 1 hour at a time.
?
N O T E
When the wireless controller is prohibited by central controller, this
function is disabled even though the indoor unit is set with the wireless
controller and the buzzer sounds.
* Only available for the combination of indoor unit and receiver kit
supporting the "0.5 ºC increment" and "Operation mode AUTO" functions
5 SENDING
COMMANDS
CONTROLLER
The operation commands are sent by pressing the required
operation switch by facing the transmitter of the controller
toward the receiver of the indoor unit.
1 When the commands are sent, the "
liquid crystal display of the controller flashes once.
2 The indication lamp (yellow) on the receiver part of the
indoor unit turns ON for an instant when the indoor unit
receives the commands.
2
PMML0414A rev.5 - 06/2019 - P5416676
HIGH
HIGH2
AUTO
*
HEAT,
DRY,
AUTO
4 Step
5 Step
6 Step
5 step
6 step
7 step
FROM
" indication on the
!
C A U T I O N
In case that the indication lamp (yellow) does not turn ON although
the commands are sent, the commands are not received by the
indoor unit. In such a case, send the commands again.
The transmitter of the controller has the vertical directivity to the
receiver, and the permissible angle for transmitting is within 50º.
However, the capable distance for transmitting gets half when
the transmitting angle is 50º, and also get shorter in case that an
electronic type light is used in the room.
LCD (Liquid crystal display) indication
When viewed from certain angles the LCD can be difficult to
read.
The viewing angle ranges from an optimal of 60º down to 30º,
as shown in the diagram.
If the viewing angle is below 30º, the indications not displayed
are slightly faded so that makes the indication be hardly
readable. It is the characteristics of this LCD, which is not
abnormality.
7 Step
Auto Swing
8 step
Indication
lamp (yellow)
turns ON for
an instant
Green Yellow Green Red
TIMER
FILTER DEF
HEAT
Receiver
?
N O T E
The above figure shows the case of a 4-way cassette type indoor unit.
The figures for other models are different partially.
6 IDENTIFYING
INSTALLED SIDE BY SIDE OPERATION
This function is used when operating several receivers or indoor
units side by side, to prevent a malfunction because of receiving
incorrect signals from the wireless remote controllers used in
other areas.
Only the communication between the paired setting is possible,
and 4 pairs (A, B, C, D) are available.
For example, the receiver set as "A" can only receive signals
from the wireless controller set as "A". It cannot receive signals
from wireless controller set as B, C or D.
Refer to the installation & maintenance manual or the operation
manual for each receiver kit or indoor unit settings. Depending
on the type of the receiver kit or the indoor unit, only setting as
Receiver part
RUN
EMERGENCY
PC-AWR
COOL
o
30
o
60
INDOOR
Direct line between
transmitter and receiver
Capable distance for
transmiting: Max 6m
Within approx 50º
(directivity)
UNITS

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis