9. Troubleshooting
Problems
Load connected to the generating set at start-up.
Fuel tap (fig. A - no. 6) closed.
Fuel level too low.
Oil level too low.
Wrong fuel used.
The engine will
Air filter (fig. A - no. 7) clogged.
not start
Fuel filter (fig. C - no. 3) clogged.
/
Oil filter (fig. B - no. 4) clogged.
Engine running
12V
abnormally
(fig. A - no. 16) defective.
Spark plug(s) (fig. E - no. 2) defective.
Starter battery (fig. A - no. 12) defective.
Fuel supply blocked or leaking.
MODYS (fig. A - no. 15) defective.
Engine red light indicator is turned on.
Blocked ventilation inlets.
Engine stops
Fuel level too low.
Oil level too low.
Fuel supply blocked or leaking.
Circuit breakers (fig. A - no. 10) not pushed in.
Faulty appliance power lead.
No
power
Power sockets (fig. A - no. 11) defective.
Alternator defective.
Appliance connected or lead defective.
Circuit breakers
tripped
Overload (see § Capacity of the generating set).
No working hours
230V fuse for MODYS and working hours counter
counter
(fig. A - no. 17) defective.
10. Specifications
Model
Maximum output / Rated output
Sound pressure level at 1 m (LpA) and measurement uncertainty
Engine type
Recommended fuel
Fuel tank capacity
Recommended oil
Oil sump capacity
Oil failure cut-out
Circuit breaker
Direct current
Alternating current
Socket type
Spark plug type
Battery
Dimensions l x w x h
Weight (without fuel)
● : standard
○ : option
AVR: The AVR system (Automatic Voltage Regulation) enables a more efficient stabilisation of the generating set voltage.
Probable causes
fuse
for
MODYS
X: not possible
Disconnect the load.
Open the fuel tap.
Fill with fuel (see § Filling with fuel).
Check the oil level and top up if necessary (see
§ Checking the oil level).
Change the fuel (see § Specifications).
Clean the air filter (see § Cleaning the air filter).
Replace the fuel filter (see § Replacing the fuel filter).
Replace the oil filter (see § Replacing the oil filter).
and
lighting
Replace the fuse (see § Replacing the protective fuses).
Check the spark plug(s) (see § Spark plug inspection)
and replace if necessary.
Recharge or replace the starter battery.
Have it checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Check
(see § Checking the oil level).
Clean the air inlet and outlet guards.
Fill with fuel (see § Filling with fuel).
Check
(see § Checking the oil level).
Have it checked, repaired or replaced.*
Push the circuit breakers in.
Change the lead.
Have it checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Disconnect the appliance and the lead.
Eliminate the overload.
Replace the fuse (see § Replacing the protective fuses).
* Operation(s) to be carried out by one of our agents.
TECHNIC 10000 E AVR C
1x2P+T 230V 10/16A - 1x2P+T 230V 16A - 1x2P+T 230V 32A
Possible solutions
the
oil
level
and
top
the
oil
level
and
top
TECHNIC 10000 E C
10000 W / 8000 W
87 dB(A) / 0.70
Kohler CH 640S
Unleaded petrol
35 L
SAE 10W30
1.9 L
X
230V - 34.8A
CHAMPION : RC12YC
89.5 x 57 x 77 cm
139 kg
up
if
necessary
up
if
necessary