ATTENTION!
Do not leave the machine unattended during operation.
Turn off the machine if you discontinue working, and pull
the mains plug.
m Electrical Connection
The electric motor is connected in a ready-to-operate
state. The connection corresponds to the relevant VDE
and DIN regulations.
The mains connection at the customer's work place
and the extension cable used must correspond to these
regulations.
Use a portable personal safety circuit-breaker (portable
residual current circuit breaker (PRCD)) if the residual
current circuit breaker (RCD) in the mains power supply
is not provided with a residual current of max. 0.03 A.
The product meets the requirements of EN 61000-3-
11 and is subject to special connection conditions. This
means that use of the product at any freely selectable
connection point is not allowed.
Given unfavorable conditions in the power supply the
product can cause the voltage to fluctuate temporarily.
The product is intended solely for use at connection
points that
a) do not exceed a maximum permitted supply imped-
ance "Z", or
b) have a continuous current-carrying capacity of the
mains of at least 100 A per phase.
As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary, that
the connection point at which you wish to operate the
product meets one of the two requirements, a) or b),
named above.
Important information
The 230 V / 50 Hz electric motor is designed for the S6
/ 40% (400 V/50 Hz S6/15%) operating mode.
The motor automatically switches off if it is overloaded.
The motor can be switched on again after a cooling-
down period (varies timewise).
Faulty electrical connecting leads
Insulation damage often occurs at electrical connecting
leads.
Causes include:
Pressure marks caused when connecting leads are
run through windows or the cracks of doors.
Folds caused by the improper attachment of running
of the connecting leads.
Cutsresulting from the crossing of the connecting
lead.
Insulation damages caused by the ripping out of the
connecting lead from the wall socket.
25