Adjusting the stop (Fig. 9)
• Position the stop (5) so that it touches the tooth base.
• Loosen the hexagon socket screw on the stop bar
(5a) and adjust its height. Retighten the hexagon
socket screw.
• By loosening the hexagonal bolt, the stop (5) can be
additionally adjusted in the groove.
Switching on and off (Fig. 10)
• To switch on, press the on/off switch (15) (position
"I"), the device starts up.
• To switch off, press the on/off switch (15) (position
"0"), the device switches off.
Sharpening the saw blade (Fig. 11)
Attention! Note the correct selection of the grind-
ing disc for the saw blade to be ground.
• Set the device as previously described.
• Switch on the machine.
• Fold down the protective panel (2).
• Turn the saw blade so that the grinding disc (4) is
between the teeth of the saw blade.
• Move the grinding unit (12) to the depth stop (14) us-
ing the handle (1).
• Carefully turn the saw blade against the grinding
disc (4) with light pressure until the cutting edge is
sharpened.
• Turn the saw blade anti-clockwise again so that the
grinding disc (4) runs freely between the teeth.
• Move the grinding unit (12) backwards again using
the handle (1).
• Turn the saw blade one tooth further.
• Repeat these procedures until all teeth are ground.
• Attention! For interlocked teeth, sand every oth-
er tooth and then set the angle of the grinding
unit (12) to the opposite side.
• Switch off the machine.

11. Electrical connection

The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the exten-
sion cable used must also comply with these regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.

12. Cleaning

Danger!
Disconnect the mains plug before carrying out any
cleaning work.
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the device directly
after every use.