Removing the
gas solenoid
valve
Fig.3
Fig.4
Fitting the gas
solenoid valve
- Push the gas hose (17) onto the magnet valve and fasten it with a hose clamp (18)
- Connect up the earthing conductors (88)
- Connect the "Gas value" control lines (89)
- Insert the gas solenoid valve (16) in the rear of the housing
Fig.5
(82)
(16)
(18)
Note! Use a new hose clamp (18) to fasten the gas hose (17)
Note! When connecting the "Gas value" control lines (89), there is no need to
ensure any particular polarity.
(82)
- TP 1500 TIG: Undo the hexagon nut
(82) - width-across 17 - on the gas
connector
- Take out the gas solenoid valve (16)
(17)
(88)
from the rear of the housing
- Open the hose clamp (18) and take out
the gas hose (17)
- Disconnect the 2 earthing conductors
(88)
- Disconnect the 2 "Gas value" control
leads (89)
(89)
- TP 1500 TIG: Tighten the hexagon nut
(82) - width-across 17 - to the gas
connector